首页 | 本学科首页   官方微博 | 高级检索  
     

基于破坏线模型的离心钢管混凝土扭转极限承载力
引用本文:金伟良,袁伟斌. 基于破坏线模型的离心钢管混凝土扭转极限承载力[J]. 建筑结构学报, 2005, 26(2): 106-111
作者姓名:金伟良  袁伟斌
作者单位:浙江大学,结构工程研究所,浙江杭州,310027;浙江大学,结构工程研究所,浙江杭州,310027
摘    要:在薄壁离心钢管混凝土构件扭转性能试验数据和离心钢管混凝土本构关系的研究基础上,针对离心钢管混凝土构 件在扭转性能试验塑性状态时钢管内离心混凝土发生约45°的脆性受拉破坏特性,提出了扭矩作用下离心钢管混凝土的 破坏线模型,由能量原理推出了管内混凝土的扭转刚度表达式,然后利用扭转刚度相等和边界条件将受压混凝土简化为 管内的等效螺旋加劲肋,提出了组合构件在纯扭转状态下极限承载力的简化计算公式。实例计算表明,本文提出的破坏线 模型其结果与他人研究成果和试验结果吻合较好。

关 键 词:薄壁离心钢管混凝土  扭转  刚度  极限承载力  破坏线模型
文章编号:1000-6869(2005)02-0106-06
收稿时间:2005-04-05
修稿时间:2003-07-01

Torsional ultimate bearing capacity of centrifugal concrete filled steel tube based on model of failure line
JIN Weiliang,YUAN Weibin. Torsional ultimate bearing capacity of centrifugal concrete filled steel tube based on model of failure line[J]. Journal of Building Structures, 2005, 26(2): 106-111
Authors:JIN Weiliang  YUAN Weibin
Affiliation:JIN Weiliang,YUAN Weibin (institute of Structural Engineering,Zhejiang University,Hangzhou,China)
Abstract:The centrifugal concrete filled steel tube (CCFT) is a new type of structural material composed of steel and concrete, and is being applied to practical engineering construction. The torsional ultimate bearing capacity of CCFT has an important and complex mechanical characteristic and it is a matter of interest to engineers concerned in this field. On the basis of analyzing the torsional test results of CCFT, the constitutive relationship of CCFT and the phenomenon of brittle crack failure line with a degree of 45 in plastic stage of centrifugal concrete filled steel tube are studied in detail. A model of failure line for torsional ultimate bearing capacity of CCFT is presented in this paper. The formula for computing torsional stiffness of centrifugal concrete with this model is obtained by the principle of strain energy. The compressive centrifugal concrete within steel tube is simplified as the equivalent spiral rib stiffener by means of equal stiffness and boundary conditions, and the related simplified formula of torsional bearing capacity of CCFT under the state of pure torsion is presented. The analytical model proposed in this paper is compared with the experimental data reported and those in research papers. Their results are in good agreement with the experimental ones.
Keywords:centrifugal concrete filled steel tube(CCFT)  torsion  stiffness  ultimate bearing capacity  model of failure line
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏