首页 | 本学科首页   官方微博 | 高级检索  
     

华能珞璜电厂“W”型火焰锅炉燃烧调整分析
引用本文:周拥军. 华能珞璜电厂“W”型火焰锅炉燃烧调整分析[J]. 重庆电力高等专科学校学报, 2014, 0(4): 50-52
作者姓名:周拥军
作者单位:华能重庆珞璜发电有限责任公司;
摘    要:介绍华能珞璜电厂引进的法国STEIN公司生产的强制循环亚临界W型火焰锅炉及燃烧系统,针对1#炉W型火焰锅炉在运行中存在的燃烧恶化问题,进行200 MW负荷燃烧试验,并通过对比分析,对制粉系统、风烟系统进行相应整改,使该锅炉在低负荷情况下安全、稳定、经济地运行。

关 键 词:W型火焰燃烧锅炉  燃烧恶化  燃烧调整

Analysis of the Combustion Adjustment of the W-shape Flame Boiler in Luohuang Power Plant of CHNG
ZHOU Yong-jun. Analysis of the Combustion Adjustment of the W-shape Flame Boiler in Luohuang Power Plant of CHNG[J]. Journal of Chongqing Electric Power College, 2014, 0(4): 50-52
Authors:ZHOU Yong-jun
Affiliation:ZHOU Yong-jun ( Chongqing Luohuang Power Generation Co. , Ltd. of CHNG,Jiangjin Chongqing 402283, China)
Abstract:This essay introduces the forced circulation subcritical W-shape flame boiler and combustion system intro-duced from COMPAGINE DE FIVES-LILLE DMS/STEIN HEURTEY/FCB CINETIC/PROCEDAIRE by Luohuang Power Plant of CHNG .In order to solve the problem of combustion deterioration during the operation of the W-shape flame boiler of 1#boiler,the 200MW combustion test has been implemented .Based on the comparative analysis ,the coal-pulverizing system and the air-gas system have been improved to ensure the safe ,stable and economical opera-tion of the boiler under the low-load condition .
Keywords:W-shape flame boiler  combustion deterioration  combustion adjustment