摘    要:针对某发电厂210MW机组锅炉效率偏低问题,优化运行调整,改造受热面吹灰器,使锅炉效率达到了设计值,机组运行的经济性提高。

关 键 词:燃煤锅炉  燃烧调整  吹灰器  锅炉效率
文章编号:1004-7948(2007)02-0040-03
修稿时间:2006-06-20

Cause analysis and Test study of the boiler efficiency in the low of 670 t/h boilers
FENG Xuan-ming. Cause analysis and Test study of the boiler efficiency in the low of 670 t/h boilers[J]. Energy Conservation, 2007, 26(2): 40-42
Authors:FENG Xuan-ming
Abstract:Aimed at the problems of boiler efficiency on the low side of 210 MW generating unit in power plant,through fathering equipment,optimizing operating adjustment,alteration heating surface soot blower,The boiler efficiency was arrived at design value,and the economic benefit of boiler machine was raised.
Keywords:pulverized coal boiler  burning adjustment  soot blower  boiler efficiency  