首页 | 本学科首页   官方微博 | 高级检索  
     


In vitro power profiles of daily disposable contact lenses
Affiliation:1. Ophthalmic Research Group, School of Life and Health Sciences, Aston University, Birmingham, United Kingdom;2. Specsavers, New Malden, London, United Kingdom;1. Department of Ophthalmology & Visual Sciences and University Hospitals Eye Institute, University Hospitals Case Medical Center, Cleveland, OH, United States;2. Department of Epidemiology & Biostatistics, Case Western Reserve University, Cleveland, OH, United States;3. Alcon Research, Fort Worth, TX, United States;4. Department of Ophthalmology, University of California, Irvine, United States;1. Aston University, Life and Health Sciences, Ophthalmic Research Group, Birmingham, UK;2. Visioncare Research Ltd, Farnham, UK;3. University of Plymouth, School of Health Professions, Faculty of Health & Human Sciences, Plymouth, UK
Abstract:PurposeTo evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles.MethodsThe Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5 mm to 5.5 mm in steps of 0.5 mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2 mm to 1.0 mm in steps of 0.2 mm).ResultsAll contact lenses showed an increase – more negative – in lens power with distance from the lens center. The amount of change varied depending on the lens. It was about 10% of lens power for DAILIES TOTAL1 (?0.29 diopters (D)), SofLens daily disposable (?0.36 D), and Proclear 1-Day (?0.32 D) whereas 1-DAY ACUVUE MOIST showed a percentage variation of 3.3% (?0.10 D). After inducing a lens decentration up to 1 mm, the power curves were shifted in the negative direction. However, the change obtained in lens power compared with well-centered position was always lower than a quarter of diopter both for all the lenses and aperture diameters.ConclusionsOur results showed a variation of the refractive power from the lens center, becoming more negative toward the periphery, with a negligible effect of the decentration for all disposable contact lenses studied.
Keywords:Contact lens  Daily disposable contact lens  Power profile  Back vertex power  Deflectometry
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号