首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal cycling and degradation mechanisms of compressive mica-based seals for solid oxide fuel cells
Affiliation:1. Instituto de Cerámica y Vidrio (CSIC), C/Kelsen 5, Campus de Cantoblanco, 28049 Madrid, Spain;2. Forschungszentrum Julich, Institute of Electronics, Engineering and Technology (ZEA-1), Juelich, Germany;3. Foseco Nederland BV, Hengelo, Netherlands;1. Jožef Stefan Institute, Department of Systems and Control, Jamova cesta 39, SI-1000, Ljubljana, Slovenia;2. VTT, Technical Research Centre of Finland, Espoo, Finland;3. Department of Industrial Engineering, Università degli Studi di Salerno, Fisciano, Italy;4. Jožef Stefan International Postgraduate School, Jamova cesta 39, SI-1000, Ljubljana, Slovenia;1. School of Electronic and Information Engineering, Yangtze Normal University, Chongqing, 408100, China;2. College of Materials Science and Engineering, Fuzhou University, Fuzhou, Fujian, 350108, China;3. Energy Research Institute @ NTU, Nanyang Technological University, Singapore, 637553, Singapore;4. Fuels and Energy Technology Institute and Department of Chemical Engineering, Curtin University, Perth, WA, 6102, Australia;5. Testing Center, Fuzhou University, Fuzhou, Fujian, 350108, China;1. Kyoto University, Department of Aeronautics and Astronautics, Kyoto, Japan;2. AGH University of Science and Technology, Faculty of Energy and Fuels, Krakow, Poland
Abstract:Thermal cycling was conducted on compressive mica seals at 800 °C in air. Thin (∼0.1 mm) Muscovite mica was pressed between a metal pipe and an alumina substrate and tested for leak rates at a stress of 100 psi in the plain (mica only) and the hybrid design. The hybrid design involves adding two glass interlayers and was found to greatly reduce the leak rates in an earlier paper. Two metals (Inconel #600 and SS430) with high and low coefficients of thermal expansion (CTE) were used to evaluate the effect of CTE mismatch on thermal cycling. The results showed that the leak rates were lower for the hybrid design than the plain micas. In addition, using the lower CTE (SS430) metal pipe resulted in lower leak rates as compared to Inconel #600 metal (high CTE). In general, the leak rates increased with the number of thermal cycles; however, it tended to level off after several tens of thermal cycles. Microstructure examination using scanning electron microscopy revealed steps, indents, fragmentation and particle formation on the mica after thermal cycling. CTE measurement of the heat-treated Muscovite mica showed a relatively low value of ∼7 ppm/°C. The cause for the degradation of the mica is discussed.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号