首页 | 本学科首页   官方微博 | 高级检索  
     

多种长焦区聚焦超声采集频率的人体甲状腺光声成像
引用本文:曾志平,谢文明,李莉,李志芳,李晖,陈树强. 多种长焦区聚焦超声采集频率的人体甲状腺光声成像[J]. 激光与光电子学进展, 2012, 0(2): 111-116
作者姓名:曾志平  谢文明  李莉  李志芳  李晖  陈树强
作者单位:医学光电科学与技术教育部重点实验室;福建省光子技术重点实验室;福建师范大学物理与光电信息科技学院;福建医科大学附属第一医院
基金项目:高等学校博士学科点专项科研基金(200803940001);新世纪优秀人才计划(NCET-04-0615);福建省自然科学基金(2009J01137)资助课题
摘    要:临床上常规的超声成像对甲状腺结节进行诊断时存在误诊和漏诊。研究了利用多种采集频率的长焦区聚焦换能器进行光声成像的方法。在模拟样品里埋入不同尺寸的血块模拟病变组织,采用不同中心频率的换能器对模拟样品进行光声成像,然后将血液注入正常人体甲状腺内部形成两处瘀血区,模拟病变甲状腺组织,经二维扫描重构出模拟病变甲状腺组织的三维光声图像。结果表明,不同频率的超声换能器对不同尺寸病灶体的探测灵敏度存在较大差异,5MHz的宽带换能器对几百微米直至毫米量级大小的病灶体均具有良好的灵敏度。获得了甲状腺及其内部两处瘀血区域的较高分辨率和对比度的三维图像。此项技术有望与超声成像技术结合,进一步提高甲状腺疾病诊断的准确率。

关 键 词:生物医学光子学  甲状腺三维成像  光声成像  甲状腺结节  换能器  采集频率

Photoacoustic Imaging of Human Thyroid Based on Long-Focal-Zone Focused Transducers with Different Frequencies
Zeng Zhiping,Xie Wenming,Li Li,Li Zhifang,Li Hui,Chen Shuqiang. Photoacoustic Imaging of Human Thyroid Based on Long-Focal-Zone Focused Transducers with Different Frequencies[J]. Laser & Optoelectronics Progress, 2012, 0(2): 111-116
Authors:Zeng Zhiping  Xie Wenming  Li Li  Li Zhifang  Li Hui  Chen Shuqiang
Affiliation:1 Key Laboratory of Optoelectronic Science and Technology for Medicine,Ministry of Education,Fuzhou,Fujian350007,China 2 Fujian Provincial Key Laboratory of Photonic Technology,Fuzhou,Fujian350007,China 3 School of Physics and Optoelectronics Technology,Fujian Normal University,Fuzhou,Fujian350007,China 4 The First Affiliated Hospital of Fujian Medical University,Fuzhou,Fujian350007, China)
Abstract:There exist misdiagnosis and missed diagnosis with routine ultrasound imaging of thyroid nodules in present clinic.A novel method employing a series of long-focal-zone focused transducers with different frequencies for photoacoustic imaging(PAI) is presented.Some blood clots in different sizes are embedded in tissue-mimicking phantom to form a phantom containing specific pathological lesions.Transducers with different frequencies are used to image this phantom photoacoustically.Furthermore,blood is injected into normal human thyroid tissue,forming two blood stasis areas.Three-dimensional imaging is available by performing two-dimensional scanning through the tissue.We demonstrate that transducers with different frequencies have different sensitivities in detecting lesions of different sizes.The broadband transducer with a center frequency of 5 MHz has a better sensitivity in detecting lesions ranging from a few hundred microns to several millimeters.Therefore,a high resolution and excellent contrast three-dimensional image of the thyroid tissue with two blood stasis areas is obtained.This technique integrated with ultrasound imaging has the potential to increase the diagnostic accuracy in clinical thyroid nodule diagnosis.
Keywords:biomedical photonics  three-dimensional thyroid imaging  photoacoustic imaging  thyroid nodules  transducer  detecting frequency