300MW循环流化床锅炉启动过程爆燃与结焦的预防及控制 |
| |
引用本文: | 陈献春,杨瑞来,陈宇,张锦坤,张善达,薛建成. 300MW循环流化床锅炉启动过程爆燃与结焦的预防及控制[J]. 电站系统工程, 2012, 0(5): 24-26,29 |
| |
作者姓名: | 陈献春 杨瑞来 陈宇 张锦坤 张善达 薛建成 |
| |
作者单位: | 福建省电力有限公司电力科学研究院;华电厦门发电厂 |
| |
摘 要: | 循环流化床锅炉启动过程爆燃与炉膛结焦事故是常见的燃烧事故,控制不当严重威胁锅炉的安全、经济运行。从循环流化床启动前预防措施、启动过程控制以及爆燃后防结焦控制等方面进行论述,以期指导运行人员操作、控制。
|
关 键 词: | 300MW 循环流化床锅炉 爆燃 结焦 |
Precaution and Control of Explosion and Coking during Startup in 300MW CFB Boiler |
| |
Affiliation: | CHEN Xian-chun,YANG Rui-lai,CHEN Yu,ZHANG Jin-kun,et al. |
| |
Abstract: | Explosion and coking in CFB boiler was the common accident,false control always threatened boiler’s safety and economical running.The precaution measures before startup,starting process control as well as anti-coking control after explosion and other aspects were discussed as to be the instructions of operation and control. |
| |
Keywords: | 300MW CFB boiler explosion coking |