A risk-based methodology for the optimal placement of hazardous gas detectors
Authors:Kang Cen  Ting Yao  Qingsheng Wang  Shengyong Xiong
Affiliation:1.School of Civil Engineering and Architecture, Southwest Petroleum University, Chengdu 610500, China;2.Department of Fire Protection & Safety and Department of Chemical Engineering, Oklahoma State University, Stillwater, OK 74078, USA;3.Wanzhou Branch Plant of Chongqing General Natural Gas Purification Plant, Southwest Oil & Gasfield Company, PetroChina, Wanzhou, Chongqing 404001, China
Abstract:Hazardous gas detection systems play an important role in preventing catastrophic gas-related accidents in process industries. Even though effective detection technology currently exists for hazardous gas releases and a majority of process installations have a large number of sensitive detectors in place, the actual operating performance of gas detection systems still does not meet the expected requirements. In this paper, a risk-based methodology is proposed to optimize the placement of hazardous gas detectors. The methodology includes three main steps, namely, the establishment of representative leak scenarios, computational fluid dynamics (CFD)-based gas dispersion modeling, and the establishment of an optimized solution. Based on the combination of gas leak probability and joint distribution probability of wind velocity and wind direction, a quantitative filtering approach is presented to select representative leak scenarios from all potential scenarios. The commercial code ANSYS-FLUENT is used to estimate the consequence of hazardous gas dispersions under various leak and environmental conditions. A stochastic mixed-integer linear programming formulation with the objective of minimizing the total leak risk across all representative leak scenarios is proposed, and the greedy dropping heuristic algorithm (GDHA) is used to solve the optimization model. Finally, a practical application of the methodology is performed to validate its effectiveness for the optimal design of a gas detector system in a high-sulfur natural gas purification plant in Chongqing, China. The results show that an appropriate number of gas detectors with optimal cost-effectiveness can be obtained, and the total leak risk across all potential scenarios can be substantially reduced. This methodology provides an effective approach to guide the optimal placement of point-type gas detection systems involved with either single or mixed gas releases.
Keywords:Leak scenario  Leak risk  Gas detection  Detector placement  Mixed-integer linear programming
本文献已被 CNKI ScienceDirect 等数据库收录!
点击此处可从《中国化学工程学报》浏览原始摘要信息
点击此处可从《中国化学工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号