Possible On‐Line Methods of Removing Oxide Deposits from Inside Steam Generator Tubes
Authors:N. Arbeau  P. Mackenzie  D. H. Lister
Abstract:In an attempt to find an on‐line method to remove oxide deposited during normal operation on the primary side of a steam generator, a series of experiments was undertaken in a high temperature recirculating autoclave system. Alloy‐600 steam generator tubes removed from a CANDU nuclear reactor were monitored on‐line with a gamma spectrometer and the effects on them of transients in pH, oxidizing condition of the coolant and temperature, alone and in combination, were attempted. Only a chemical process—the addition of a mixture of ethylenediaminetetraacetic acid (EDTA) and citric acid—was effective in removing radioactivity and, therefore, oxide.
Keywords:steam generator tubes  chemical cleaning  oxide removal ph  oxidizing  reducing