首页 | 本学科首页   官方微博 | 高级检索  
     

给水厂混凝剂技术经济性验证流程重构及应用
引用本文:王文浩,王瑞彬,郭小雅,陈发明,贾瑞宝,王永磊.给水厂混凝剂技术经济性验证流程重构及应用[J].给水排水,2019,45(7):17-23.
作者姓名:王文浩  王瑞彬  郭小雅  陈发明  贾瑞宝  王永磊
作者单位:山东省城市供排水水质监测中心,济南250100;山东建筑大学,济南250101;济南水务集团有限公司,济南,250118;山东省调水工程运行维护中心,济南,250100;山东省城市供排水水质监测中心,济南,250100;山东建筑大学,济南,250101
基金项目:水体污染控制与治理科技重大专项;水体污染控制与治理科技重大专项;山东省"泰山学者"岗位项目
摘    要:在前期研究模糊综合评价方法的基础上建立了一套普适性的给水厂混凝剂评估验证流程方法,通过烧杯试验、中试优化评估混凝剂适用性及优选投加量,并结合技术经济性因素在实际水厂开展了规模化的验证,以期为水厂混凝剂的适用性筛选及其优化使用提供借鉴。烧杯试验采用标准流程对水厂常用的PAFC及PAC进行评价对比,中试阶段对烧杯试验所选投加量进行验证,生产验证主要是在经济投加量下,检测出水各项指标。结果显示:PAFC对目标水体的适用效果较好且优于PAC。烧杯及中试验证发现药剂的最佳投加量为4mg/L,但在生产验证阶段兼顾了技术经济性因素,确定最适投加量应为2mg/L。在此情况下,其出水浊度、TOC、CODMn以及UV254的去除率分别达到了89.87%、7.5%、33.01%以及44.57%,絮体平均粒径达到了625μm,投药成本为0.07元/m3。通过全流程评估验证综合评价:目标给水厂当前所用混凝剂以及投加量是相对科学合理的。

关 键 词:给水厂  混凝剂  去除能效  技术经济性  验证体系

Reconstruction and demonstration application of technical and economic evaluation and verification process of coagulant for water treatment plant
Wang Wenhao,Wang Ruibin,Guo Xiaoya,Chen Faming,Jia Ruibao,Wang Yonglei.Reconstruction and demonstration application of technical and economic evaluation and verification process of coagulant for water treatment plant[J].Water & Wastewater Engineering,2019,45(7):17-23.
Authors:Wang Wenhao  Wang Ruibin  Guo Xiaoya  Chen Faming  Jia Ruibao  Wang Yonglei
Affiliation:(Shandong Province Water Supply and Drainage Monitoring Center,Ji'nan 250100,China;Shandong Jianzhu University,Ji'nan 250101,China;Jinan Water Group Co.,Ltd.,Ji'nan 250118,China;Shandong Province Bureau of Jiaodong Water Diversion,Ji'nan 250100,China)
Abstract:In order to evaluate and select the coagulant in the water treatment plant scientifically and effectively.In the early stage of the research study in this paper the fuzzy comprehensive evaluation method on the basis of the established a set of general assessment process validation method for waterworks coagulants,mainly through beaker test,pilot test optimization evaluation applicability and coagulant dosing quantity optimization,and combined with the technical economical factor in actual water carried out large-scale practical validation,so as to the applicability of the waterworks coagulant selection and optimization of use for reference.In the beaker test,standard process is adopted to evaluate and compare the PAFC and PAC commonly used in the water treatment plant.In the pilot test stage,the selected dosage of the beaker test is verified.The production verification is mainly to test the results of water indexes under the economic dosage.The results show that PAFC is better than PAC in the application of target water.In the beaker test and pilot test,it is found that the optimal dosage is 4 mg/L,but the technical and economic factors are taken into account in the production verification stage,and the optimal dosage is determined to be 2 mg/L.The removal rates of turbidity,TOC,CODMnand UV254 reach 89.87%,7.5%,33.01% and 44.57%,respectively.The comprehensive evaluation is verified through the whole process evaluation that the target coagulant and dosage used in the water plant are relatively scientific and reasonable.
Keywords:Water treatment plant  Coagulant  Removal efficiency  Technical and economic  Verification system
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号