首页 | 本学科首页   官方微博 | 高级检索  
     


Fouling of cellulose acetate tubular reverse osmosis modules treating the industrial water in Tokyo
Authors:Shoji Kimura  Shin-Ichi Nakao
Affiliation:Department of Chemical Engineering, University of Tokyo, Bunkyo-ku, Tokyo 113 Japan
Abstract:The Tokyo industrial water supply was treated in tubular reverse osmosis modules in order to investigate the effect of feed velocity and type of membrane on fouling. Rate of fouling by mechanical compaction was proportional to time, whose power was dependent on the initial flux of membrane, while fouling by the deposit of suspended solids tended to cease after the flux was down to a certain value, which was dependent on the feed velocity. Results were analysed by the deposit accumulation model. The deposit layer had a salt-rejecting ability, and its permeability was calculated.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号