首页 | 本学科首页   官方微博 | 高级检索  
     


An Intercomparison Study of Analytical Methods for the Determination of Magnesium in Low Alloy Steel
Authors:Sebastian Recknagel  Silke Richter  Fredrik Reinholdsson  Jean Pettersson  Ingemar Gustavsson
Affiliation:1. BAM Bundesanstalt für Materialforschung und ‐prüfung, Richard‐Willst?tter‐Strasse 11, D‐12489 Berlin, Germany;2. Ovako Hofors AB,SE 813 82 Hofors, Sweden;3. Uppsala University, Box 599, SE 751 24 Uppsala, Sweden;4. Gustavsson Consulting, Skeppargatan 23, SE 114 52 Stockholm, Sweden
Abstract:In an intercomparison study three low alloy steel materials were analyzed on their content of the trace element Mg, and five different analytical techniques were used, namely spark‐OES, inductively coupled plasma optical emission spectrometry (ICP‐OES), inductively coupled plasma time of flight mass spectrometry (ICP‐TOFMS), inductively coupled plasma quadrupole mass spectrometry (ICP‐QMS), and glow discharge mass spectrometry (GD‐MS). Solid steel discs were used for analysis with spark‐OES and GD‐MS. For the analyses with ICP‐OES, ICP‐TOFMS, and ICP‐QMS steel chips were wet‐digested in aqua regia, and the wet‐digestion was performed either in polypropylene tubes placed in a heating block or in Teflon pressure vessels using a microwave assisted system. The Mg concentrations obtained for the three steel materials were: 2.0, 2.8, and 10.3 µg g?1, respectively, and the spread in results was acceptable, giving RSD values in the range of 20–30%.
Keywords:Mg  steel  spark‐OES  ICP‐OES  ICP‐MS  GD‐MS