Error detection for PHEV,BEV and stationary battery systems |
| |
Authors: | Michael A. Roscher Robert M. Kuhn Harry Döring |
| |
Affiliation: | 2. TUM CREATE 1 CREATE Way Singapore 138602, Singapore |
| |
Abstract: | Battery cells being electrically disconnected resulting from degradation, mechanical stress, or corrosion can lead to hazardous situations during operation of electric vehicles or storage systems in stationary applications. The mentioned errors can be acceptable in some cases when cells or cell strings are connected in parallel, but the failure is to be detected in order to guarantee the reliable and safe operation of the battery system. A method enabling the estimation whether individual battery cells are faulty (cell error or electrically disconnected) by evaluating the mean impedance and capacity information of cell groups is introduced and validated. |
| |
Keywords: | Battery system State estimation Fault detection Reliable operation |
本文献已被 ScienceDirect 等数据库收录! |