Experimental investigation and theoretical analysis of the solar adsorption cooling system in a green building
Authors:XQ Zhai  RZ Wang
Affiliation:1. School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology, Islamabad, Pakistan;2. Department of Mechanical Engineering, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia;1. Beijing Key Laboratory of Heat Transfer and Energy Conservation, Beijing University of Technology, Beijing 100124, China;2. National Institute of Metrology, Beijing 102200, China;1. Unité de Développement des Equipements Solaires, UDES, Centre de Développement des Energies Renouvelables, CDER, 42415 Tipaza, Algeria;2. LME, University Hassiba BENBOUALI of Chlef, Hay Salem National Road No 19, 02000 Chlef, Algeria;3. FIMA, University DJILALI BOUNAAMA of Khemis-Miliana, Road of Theniet El Had, 44225 Khemis-Miliana, Algeria
Abstract:A solar adsorption cooling system was constructed in the green building of Shanghai Institute of Building Science. The system consisted of evacuated tube solar collector arrays of area 150 m2, two adsorption chillers with nominal cooling capacity of 8.5 kW for each and a hot water storage tank of 2.5 m3 in volume. A mathematical model of the system was established. According to experimental results under typical weather condition of Shanghai, the average cooling capacity of the system was 15.3 kW during continuous operation for 8 h. The theoretical analysis of the system was verified and found to agree well with the experimental results. The performance analysis showed that solar radiant intensity had a more distinct influence on the performance of solar adsorption cooling system as compared with ambient temperature. It was observed that the cooling capacity increased with the increase of solar collector area, whereas, solar collecting efficiency varied quite contrary. With the increase of water tank volume, cooling capacity decreased, while, the solar collecting efficiency increased. The system performances can be enhanced by increasing the height-to-diameter ratio of water tank. Additionally, it was observed that solar collecting efficiency decreased with the increase of the initial temperature of water in the tank; however, cooling capacity varied on the contrary. Also can be seen is that optimum nondimensional mass flow rate is 0.7 when the specific mass flow rate exceeds 0.012 kg/m2 s.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号