首页 | 本学科首页   官方微博 | 高级检索  
     

氟离子选择电极法测定牙膏中的氟
引用本文:刘青,胡君,涂高发,刘礼武. 氟离子选择电极法测定牙膏中的氟[J]. 福建分析测试, 2012, 0(6): 52-54
作者姓名:刘青  胡君  涂高发  刘礼武
作者单位:深圳市粤环科检测技术有限公司,广东 深圳 518103
摘    要:验证了离子选择电极法测定氟化物的特征指标,结果表明:测定下限为0.04 mg/L,标本标准偏差为0.0026,相对标准偏差<2.7%,回收率在97~103%.说明该方法的精密度好,准确度高,符合质量控制要求。

关 键 词:氟离子选择电极  牙膏  

Fluorine Ion-Selective Electrode Analysis To Determine The Fluoride of Toothpaste
Liu Qing,Hu Jun,Tu Gao-fa,Liu Li-wu. Fluorine Ion-Selective Electrode Analysis To Determine The Fluoride of Toothpaste[J]. Fujian Anal Ysis & Testing, 2012, 0(6): 52-54
Authors:Liu Qing  Hu Jun  Tu Gao-fa  Liu Li-wu
Affiliation:(SHEN ZHEN YUEHUANKE DETECTED TECHNOLOGY,Shenzhen,Guangdong 518103,China)
Abstract:The characteristic factors of fluorine ion-selective electrode analysis to determine the fluoride are verified.It shows that the RQL is 0.04 mg/L,the standard deviation is 0.0026, the RSD is 〈2.7 %,and the rate of recovery is between 97-103%. The precision and accuracy of this method is fine and meets the requirement of quality control.
Keywords:fluorine ion-selective electrode  toothpaste  fluoride