首页 | 本学科首页   官方微博 | 高级检索  
     


Limited reinforced space in segmental retaining walls
Authors:Dov Leshchinsky   Yuhui Hu  Jie Han
Affiliation:

a Department of Civil and Environmental Engineering, University of Delaware, Newark, DE 19716, USA

b Civil, Environmental and Architectural Engineering (CEAE) Department, The University of Kansas, 1530 W. 15th Street, Lawrence, Kansas, 66045-7609, USA

Abstract:Current design of geosynthetic reinforced segmental retaining walls considers an a priori limitless length for reinforcement installation. Such length is typically 0.5–0.7 times the height of the wall. However, often there are constraints on such space; e.g., bedrock formation located at a small distance behind the facing. The objective of this note is to introduce a procedure for assessing the required long-term strength of the reinforcement while considering its limited length. Predictions by a conventional slope stability analysis were first checked against a continuum-mechanics based numerical analysis. Upon obtaining good agreement, a design chart was developed. The chart enables the determination of the reduction in the lateral earth pressure coefficient due to the constrained space. The revised earth pressure coefficient can be used with current analytical methods to account for the limited space. The results appear to be valid for conventional walls retaining a limited volume of soil. Comparison with limited experimental results for unreinforced backfill shows reasonably good agreement.
Keywords:Geosynthetic   MSE walls   Retaining walls   Lateral earth pressure   Limit equilibrium
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号