首页 | 本学科首页   官方微博 | 高级检索  
     

两种空调送风方式在织造车间运用的比较分析
引用本文:李帆,刘刚. 两种空调送风方式在织造车间运用的比较分析[J]. 山东纺织科技, 2005, 46(4): 19-22
作者姓名:李帆  刘刚
作者单位:东华大学,上海,200051;东华大学,上海,200051
摘    要:介绍了织造车间传统的全面送风方式和现代的全面与局部相结合的送风方式,根据实际工程对两种送风方式在温湿度、气流组织、能耗等方面进行比较分析。结果表明,现代送风方式能够较好地满足生产工艺的要求,且节能效果显著,是极佳的织造车间空调送风方式。

关 键 词:织造  空调  局部送风  温湿度  气流组织  节能
文章编号:1009-3028(2005)04-0019-04
收稿时间:2005-07-06
修稿时间:2005-07-06

Analysis and Comparison of Two Kinds of Air Supply System Used in Weaving Workshop
LI Fan,LIU Gang. Analysis and Comparison of Two Kinds of Air Supply System Used in Weaving Workshop[J]. Shandong Textile Science & Technology, 2005, 46(4): 19-22
Authors:LI Fan  LIU Gang
Abstract:This paper introduced two kinds of air conditioning system used in weaving workshop,that is, traditional total air supply system and modern total and local combined air supply system. It also made an analysis of these two systems on temperature and humidity, air flow organization and energy saving according to the existed projects . The result shows that the modern air supply system can meet the requirement of the process and has great effect on energy saving . It is a perfect air supply system in the weaving workshop.
Keywords:weaving   air conditioning   local air supply   temperature and humidity   flow organization   energy saving
本文献已被 CNKI 维普 万方数据 等数据库收录!