首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of serotonin on a glassy carbon electrode modified by electropolymerization of meso-tetrakis(2-aminophenyl)porphyrin and single walled carbon nanotubes
Authors:Kim Seul Ki  Ahmed Mohammad Shamsuddin  Jeong Haesang  You Jung-Min  Jeon Seungwon
Affiliation:Department of Chemistry and Institute of Basic Science, Chonnam National University, Gwangju 500-757, Korea.
Abstract:A chemically modified electrode poly(TAPP)-SWNT/GCE] was prepared by electropolymerization of meso-tetrakis(2-aminophenyl)porphyrin (TAPP)-single walled carbon nanotubes (SWNT) on the surface of a glassy carbon electrode (GCE). This modified electrode was employed as an electrochemical biosensor for the determination of serotonin concentration and exhibited a typical enhance effect on the current response of serotonin and lower oxidation overpotential. The biosensor was very effective to determined 5-HT in a mixture. The linear response was in the range 2.0 x 10(-7) to 1.0 x 10(-5) M, with a correlation coefficient of 0.999 i(p)(microA) = 3.406 C (microM)+0.132] on the anodic current, with a detection limit of 1 x 10(-9) M. Due to the relatively low currents and different potentials in the electrochemical responses to ascorbic acid and dopamine, the modified electrode is a useful and effective sensing device for the selective and sensitive serotonin determination in the presence of ascorbic acid and dopamine.