The COP of absorption and resorption heat pumps with ammonia-water as working fluidLe coefficient de performance des pompes de chaleur à absorption et à résorption avec de l'eau-ammoniac comme fluide de travail |
| |
Authors: | HD Baehr |
| |
Affiliation: | The author is from the Institut für Thermodynamik, Hochschule der Bundeswehr Hamburg, Hamburg, Federal Republic of Germany |
| |
Abstract: | A study has been made of the use of an absorption heat pump for the heating of buildings. With the aid of a computerized parameter study, one can evaluate the COP that can be achieved with single-stage absorption heat pumps as a function of external parameters and the irreversibilities in the components of the heat pump. An NH3H2O mixture was used. The condenser was replaced by a resorber in order to avoid the excessive pressure in the former. The COP is thus evaluated for this resorption cycle as a function of the resorption pressure. The absorber pressure and the temperature of the weak solution leaving the generator were optimized in order to achieve a better COP. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |