首页 | 本学科首页   官方微博 | 高级检索  
     


Heat exchangers for he II cooling loops with self-sustained fountain effect pumps
Authors:A. Hofmann, A. Khalil,H. P. Kr  mer
Affiliation:A. Hofmann, A. Khalil,H. P. Krämer
Abstract:A cooling cycle with He II convection driven by self-sustained fountain effect pumps is being investigated. Special attention is drawn to the problem of heat transfer at both ends of the superfilter of this loop. The heat exchanger requirements are derived from theoretical considerations on the degradation of the cooling characteristic effected by non-perfect heat exchangers. A shell and tube type heat exchanger, optimized for the warm end of the filter has been operated in this loop with a thermal load of up to 9 W, with 2.8 g s−1 maximum helium flow rate and with inlet temperatures between 1.8 and 3.4 K. Its performance is well described by computations. A different heat exchanger design with finned Cu walls is suggested for the cold end of the pump. Some considerations on its optimization are given.
Keywords:helium   heat transfer   fountain effect pumps
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号