摘    要:针对氯气系统压力偏高(达0.20 MPa)且不稳定的情况进行分析,确认捕集器后液氯工段管道细是引起氯气压力波动的原因。将氯气管道由DN80改为DN125,使氯气压力稳定在0.09 MPa。

关 键 词:氯气  压力波动  原因  管道

Analysis on the causes of chlorine system pressure fluctuation
ZHANG Shimin , ZHANG Miao , CUI Li.Analysis on the causes of chlorine system pressure fluctuation[J].Chlor-Alkali Industry,2012,48(7):20-21.
Authors:ZHANG Shimin  ZHANG Miao  CUI Li
Affiliation:1. Shaanxi Hongxing Chemical Industry Co., Ltd., Weinan 714000, China; 2. Fangda Jinhua Chemical Technology Co. , Ltd. ,Huludao 125001, China)
Abstract:The status that the pressure of chlorine gas system was high up to 0.20 MPa and unstable was analyzed. It was determined that the chlorine gas pipe with small diameter behind a trap in liquid chlorine section accounted for the fluctuation of chlorine gas pressure. After the diameter of chlorine gas pipe was changed from DN80 to DN 125, the pressure of chlorine gas was stabilized at 0.09 MPa.
Keywords:chlorine gas  pressure fluctuation  cause  pipe