首页 | 本学科首页   官方微博 | 高级检索  
     


Drop breakup and entrainment in the updraft
Authors:Hai-Feng Liu  Yu-Fan Wang  Hui Zhao  Wei-Feng Li  Jian-Liang Xu
Affiliation:1. Shanghai Engineering Research Center of Coal Gasification, East China University of Science and Technology, Shanghai 200237, China

Contribution: ​Investigation (equal), Methodology (equal);2. Shanghai Engineering Research Center of Coal Gasification, East China University of Science and Technology, Shanghai 200237, China;3. Shanghai Engineering Research Center of Coal Gasification, East China University of Science and Technology, Shanghai 200237, China

Contribution: Resources (equal)

Abstract:This study aims to investigate the characteristics of gas–liquid countercurrent contact processes. In spray towers or other applications, several drops containing pollutants are entrained by the updraft flue gas, which can easily cause environmental pollution. Traditionally, this drop entrainment phenomenon is alleviated by increasing the diameter of the drops. However, the breakup of a large drop would also cause drop entrainment to become serious, a process referred to as secondary atomization. Herein, we propose the boundary of three drop modes in the updraft: drop falling mode, reverse entrainment mode, and breakup entrainment mode. The critical Weber number (We) is the key dimensionless number marking the beginning of the drop breakup. The ratio of the drag force to gravity and We are proposed as criteria for the drop entrainment.
Keywords:drop breakup  entrainment  gas–liquid countercurrent  secondary atomization