摘    要:针对1000 kV特高压交流输电线路带电作业绝缘工器具的试验电压偏严格,造成工器具非正常损坏的问题,深入分析了1000 kV交流输电线路带电作业工况下的工频及操作过电压水平,同时开展了1000 kV特高压带电作业绝缘工器具试验的电压选取及其安全裕度研究.综合分析后提出了较为合理的试验电压以及安全裕度范围,并对提出的修订...

关 键 词:特高压交流输电  带电作业  绝缘工器具  试验电压  电压修订
收稿时间:2020-06-11
修稿时间:2020-09-28

Test Voltage Optimization and Safety Margin of Insulation Tools for Live Working of UHV AC Transmission Lines
ZHU Kai,FANG Yuqun,YU Guangkai. Test Voltage Optimization and Safety Margin of Insulation Tools for Live Working of UHV AC Transmission Lines[J]. Electric Power, 2021, 54(7): 132-140. DOI: 10.11930/j.issn.1004-9649.202006146
Authors:ZHU Kai  FANG Yuqun  YU Guangkai
Affiliation:1. Jinhua Power Supply Company, State Grid Zhejiang Electric Power Co., Ltd, Jinhua 321000, China;2. China Electric Power Research Institute Co., Ltd, Wuhan 430000, China
Abstract:In view of the problem that the test voltage of live working insulation tools for 1 000 kV UHV AC transmission lines is too high, causing abnormal damage to the work tools, we made an in-depth analysis of the power frequency and operating overvoltage level for the live working condition of 1 000 kV AC transmission lines. And at the same time, a research was carried out on the voltage selection and safety margin for the 1 000 kV UHV live working insulation tool test. After comprehensive analysis, the reasonable test voltage and safety margin range are put forward, and the proposed revision values are verified by a number of tests including power frequency withstand voltage test, insulation material electrical performance test and live working safety test, which have fully proved the rationality of the proposed revision values.
Keywords:UHV AC transmission  live working  insulation tools  test voltage  voltage revision  