摘    要:针对某风电场双馈机组的现场高电压穿越测试中变流器故障导致风电机组脱网的问题,通过对风电机组变流器过压的深入分析,提出了一种风电机组在高电压穿越期间动态调整变流器母线参考电压的方法,解决了现场变流器过压保护导致风电机组脱网的问题。通过现场实测验证了所提策略的有效性,为风电机组的高电压穿越能力改造提供借鉴,为防范直流送端新能源电力系统的震荡提供了有益参考。

关 键 词:直流特高压  风电机组  高电压穿越  现场实测  
收稿时间:2019-01-19
修稿时间:2020-03-24

Influence of Converter DC Bus Overvoltage on Wind Turbine High Voltage Ride Through Capabilities
ZHANG Guangru,BAI Runqing,ZHU Hongyi,YANG Yong,XU Honglei,MA Xiping,DONG Kaisong. Influence of Converter DC Bus Overvoltage on Wind Turbine High Voltage Ride Through Capabilities[J]. Electric Power, 2020, 53(11): 106. DOI: 10.11930/j.issn.1004-9649.201901035
Authors:ZHANG Guangru  BAI Runqing  ZHU Hongyi  YANG Yong  XU Honglei  MA Xiping  DONG Kaisong
Affiliation:1. State Grid Gansu Electric Power Research Institute, Lanzhou 730070, China;2. State Grid Gansu Electric Power Company, Lanzhou 730030, China
Abstract:Off-grid occurred in a wind farm caused by converter fault during field test of the DFIG (doubly feed induction generator) high voltage ride through (HVRT) capabilities. Through an in-depth analysis of the overvoltage of the wind turbine converter, a method was proposed for dynamic adjustment of converter DC bus reference voltage during wind turbine HVRT, which solved the off-grid problem of wind turbines caused by overvoltage protection of converter. Field test verified the effectiveness of the proposed method, which can provide useful experience for improving the wind turbine HVRT capabilities, and a reference for preventing the oscillation of renewable energy DC sending-end power system.
Keywords:UHV DC  wind turbine  high voltage ride through  field test  
点击此处可从《中国电力》浏览原始摘要信息
点击此处可从《中国电力》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号