摘    要:为扩大炼焦煤资源、降低焦化企业配煤成本,通过坩埚焦试验和40 kg小焦炉试验考察了 3种气煤(分别记为QM1、QM2和QM3)替代某焦化企业工业配煤方案中1/3焦煤的可行性,并采用镜质体反射率分布图对气煤的适宜配入比例进行了优化.结果表明,在原生产配煤方案中,当气煤替换比为8%时,焦炭冷态强度变化较小,但其热态强度均有...

关 键 词:气煤  配煤炼焦  冷态强度  热态强度  镜质体反射率分布图

Optimization test for coal blending scheme of replacing 1/3 coking coal with gas coal
PAN Lin-hui,HUANG Sheng,SHI Feng,XU Jia,ZHANG Kai-xing,ZHANG De-xiang. Optimization test for coal blending scheme of replacing 1/3 coking coal with gas coal[J]. China Metallurgy, 2022, 32(1): 90-96. DOI: 10.13228/j.boyuan.issn1006-9356.20210313
Authors:PAN Lin-hui  HUANG Sheng  SHI Feng  XU Jia  ZHANG Kai-xing  ZHANG De-xiang
Affiliation:1. Department of Energy and Chemical Engineering, School of Resources and Environmental Engineering, East China University of Science and Technology, Shanghai 200237, China;2. Marketing Center, Yanzhou Coal Mining Co., Ltd., Jining 273500, Shandong, China;3. International Trade Branch Office, Yanzhou Coal Mining Co., Ltd., Jining 273500, Shandong, China
Abstract:In order to expand coking coal resources and reduce coal blending cost of coking enterprises, the feasibility of three gas coals (termed as QM1, QM2 and QM3) replacing 1/3 coking coal in industrial coal blending scheme was investigated through crucible coke and 40 kg coke oven tests, and the appropriate proportion of gas coal was optimized by vitrinite reflectance distribution diagram. The results showed that at the gas coal replacement ratio of 8%, the variation for cold strength of cokes were tiny, but its thermal strength was deteriorated, in which the CRI increased from 26.60% to 27.97%-29.79%, and the CSR decreased from 64.14% to 61.14%-62.82%. When the replacement ratio for QM3 was 5%, the coke quality was similar to that of original industrial blending scheme. While the replacement ratio for QM1 and QM2 was 5%, the CRI of cokes was about 2% higher and CSR was about 2% lower than those of original industrial coal blending scheme. In view of industrial coal blending scheme for producing primary metallurgical coke, it was feasible to replace the 1/3 coking coal with 5% QM3, which could reduce the cost of coal at least 15 yuan per ton of coke, and the appropriate proportion of QM1 and QM2 should be less than 5%.
Keywords:gas coal  coal blending scheme  cold intensity  thermal intensity  vitrinite reflectance distribution diagram   