首页 | 本学科首页   官方微博 | 高级检索  
     


Low-noise magnetic force microscopy with high resolution by tip cooling
Authors:Saito   H. Sunahara   R. Rheem   Y. Ishio   S.
Affiliation:Dept. of Mater. Sci. & Eng., Akita Univ., Japan;
Abstract:Low-noise magnetic force microscopy (MFM) was realized by using a conventional high-vacuum MFM with homemade tip-cooling equipment. The noise level of the MFM at a tip temperature of 130 K was estimated at /spl mu/N/m order. High spatial resolution of 10 nm was obtained for observing high-density recording media with recording density of 1000 kfci. The improvement of resolution by tip cooling was a result of the reduction of thermodynamic noise of a cantilever and the effective reduction of tip-sample distance due to the magnetic hardening of a tip.
Keywords: