首页 | 本学科首页   官方微博 | 高级检索  
     


Master Logic Diagram: method for hazard and initiating event identification in process plants
Authors:Papazoglou I A  Aneziris O N
Affiliation:System Reliability and Industrial Safety Laboratory, Institute of Nuclear Technology-Radiation Protection, National Center for Scientific Research Demokritos, P.O. Box 60228, 15310, Aghia Paraskevi, Greece. yannisp@ipta.demokritos.gr
Abstract:Master Logic Diagram (MLD), a method for identifying events initiating accidents in chemical installations, is presented. MLD is a logic diagram that resembles a fault tree but without the formal mathematical properties of the latter. MLD starts with a Top Event "Loss of Containment" and decomposes it into simpler contributing events. A generic MLD has been developed which may be applied to all chemical installations storing toxic and/or flammable substances. The method is exemplified through its application to an ammonia storage facility.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号