首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal Characteristics in a Tube With Loose-Fit Perforated Twisted Tapes
Authors:Sibel Gunes  Ersin Karakaya
Affiliation:1. Department of Mechanical Engineering, Erciyes University, Kayseri, Turkey sgumus@erciyes.edu.tr;3. Department of Mechanical Engineering, Erciyes University, Kayseri, Turkey
Abstract:Enhanced heat transfer and pressure loss in a tube with loose-fit perforated twisted tapes were experimentally investigated. The effects of the twist ratio and the hole diameter ratio were also described. A constant twisted tape width of 52 mm, which is lower than the tube inside diameter of 56 mm, was used in order to reduce excessive pressure drops associated with full-width twisted tape elements. The tests were conducted using the tapes with three different ratios of pitch length of twisted tape to inner diameter of tube (twist ratios = 2, 2.5, 3) and three different ratios of hole to inner diameter (diameter ratios = 0.0714, 0.107, 0.143) in a range of Reynolds number 4860 to 24,130 under uniform heat flux conditions. The experimental findings revealed that the Nusselt number, friction factor, and thermal performance factor increase with decreasing twist ratio and hole diameter ratio. The maximum value of thermal performance factor of 1.27 was achieved for the case at a twist ratio of 2 and a hole diameter ratio of 0.0714. Eventually, the experimental results of Nusselt number, friction factor and thermal performance factor were correlated, and the deviations determined for Nusselt number, friction factor, and thermal performance factor were within ±7%, ±8%, and ±6%, respectively.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏