首页 | 本学科首页   官方微博 | 高级检索  
     

水泥土搅拌桩芯样电阻率特性的应用研究
引用本文:董晓强 宋志伟 张少华 杨波 武思宇. 水泥土搅拌桩芯样电阻率特性的应用研究[J]. 土木工程学报, 2016, 49(10): 88-94
作者姓名:董晓强 宋志伟 张少华 杨波 武思宇
作者单位:1. 太原理工大学, 山西太原 030024;2. 北京中岩大地工程技术有限公司, 北京 100041
摘    要:为了进一步论证应用电阻率法检测水泥土搅拌桩施工质量的可行性,以现场钻取的水泥土芯样为研究对象,进行了不同交流电频率下的电阻率、无侧限抗压强度和渗透试验。结果表明:电阻率随电流频率的增加而减小,根据电阻率的变化趋势可以发现存在一个临界频率50kHz;水泥土电阻率和无侧限抗压强度均随土层的变化呈现一致的变化规律,但是水泥土电阻率和渗透系数均随土层的变化呈现相反的变化规律;水泥土无侧限抗压强度和电阻率、渗透系数和电阻率、变形模量和无侧限抗压强度之间均呈较好的线性关系;建立了可以通过水泥土电阻率估计其无侧限抗压强度、变形模量和渗透系数的关系式。研究结果可为现场检测水泥土施工质量提供参考。

关 键 词:水泥土   电阻率   无侧限抗压强度   渗透系数   变形模量  

Application study of electrical resistivity characteristics of core samples from soil-cement mixing piles#br#
Dong Xiaoqiang Song Zhiwei Zhang Shaohua Yang Bo Wu Siyu. Application study of electrical resistivity characteristics of core samples from soil-cement mixing piles#br#[J]. China Civil Engineering Journal, 2016, 49(10): 88-94
Authors:Dong Xiaoqiang Song Zhiwei Zhang Shaohua Yang Bo Wu Siyu
Affiliation:1. Taiyuan University of Technology, Taiyuan 030024, China;2. Beijing Zhongyan-Geotech Engineering Technology Co., Ltd., Beijing 100041, China
Abstract:In order to further demonstrate the application of electrical resistivity method to detecting the quality of soil-cement mixing piles, the soil-cement core samples taken from site were studied and tested. Based on the tests of core samples for the electrical resistivity under different alternating current frequencies, unconfined compressive strength and permeability, it is found that the electrical resistivity may decrease with the increase of current frequency, and there exists a critical frequency of 50kHz during the variation of electrical resistivity; with the changing of soil layer, both electrical resistivity and unconfined compressive strength have similar variation laws, but the electrical resistivity and the permeability coefficient have opposite variations with soil layer; good linear relationships between unconfined compressive strength and electrical resistivity, between coefficient of permeability and electrical resistivity, or between deformation modulus and unconfined compressive strength can be observed. Furthermore, the formulas for determining unconfined compressive strength, deformation modulus and coefficient of permeability according to electrical resistivity were established. The research results and conclusions can be referred when detecting the quality of soil-cement mixing piles in site.
Keywords:soil-cement   electrical resistivity   unconfined compressive strength   coefficient of permeability   deformation modulus  
本文献已被 CNKI 等数据库收录!
点击此处可从《土木工程学报》浏览原始摘要信息
点击此处可从《土木工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号