首页 | 本学科首页   官方微博 | 高级检索  
     


Boiling of ammonia/lubricant mixture on a horizontal enhanced tube in a flooded evaporator with inlet vapor quality
Authors:J Zheng  M-C Chyu  Z Ayub  
Affiliation:aTexas Tech University, Lubbock, TX, USA;bIsotherm Inc., Arlington, TX, USA
Abstract:In a flooded evaporator of an ammonia vapor-compression refrigeration system, boiling commonly takes place with ammonia mixed with compressor lubricant and subjected to a vapor quality at the inlet of the evaporator. In the present study, flooded boiling tests of ammonia on an enhanced tube under simultaneous influence of a miscible lubricant and inlet quality were conducted. The results suggest that the boiling heat transfer coefficient increases with both saturation temperature and heat flux. The coefficient slightly increases or does not significantly vary with the inlet quality. The coefficient in general is decreased by adding lubricant to the refrigerant, but the coefficient does not necessarily decrease as the lubricant concentration increases. The lubricant effect is generally more significant than the inlet quality effect. A correlation was developed based on the present data for flooded boiling of lubricant/ammonia mixture on an enhanced horizontal tube under the influence of inlet quality.
Keywords:Refrigeration system  Flooded evaporator  Experiment  Pool boiling  Ammonia  Lubricant  Horizontal tube  Enhanced surface  Heat transfer coefficientMots clé  s: Systè  me frigorifique  É  vaporateur noyé    Expé  rimentation  É  bullition libre  Ammoniac  Lubrifiant  Tube horizontal  Surface amé  lioré  e  Coefficient de transfert de chaleur
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏