首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental verification of the field synergy principle
Authors:Liang-Dong Ma  Zeng-Yao LiWen-Quan Tao
Affiliation:State Key Laboratory of Multiphase Flow in Power Engineering, School of Energy and Power Engineering, Xi'' an Jiaotong University, Xi'' an, PR. China
Abstract:In this paper, the basic idea of the field synergy principle (FSP) is briefly reviewed and is validated experimentally by incompressible flow through a square duct with an imposed temperature difference between vertical walls and perfectly insulated on the horizontal walls. This creates a situation where the steamwise flow velocity is normal to the cross section temperature gradient. The experimental results show the independency of crosswise heat transfer rate on the steamwise flow velocity. Detailed discussion is provided to account for some minor deviation from the expected results of FSP.
Keywords:Field synergy principle  Experimental study  Enhanced heat transfer
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏