首页 | 本学科首页   官方微博 | 高级检索  
     


Standardization and validation of ATP luminometry as a diagnostic tool to assess the cleanliness of feeding equipment in preweaning calves
Affiliation:1. Département des Sciences Cliniques, Faculté de Médecine Vétérinaire, Université de Montréal, St-Hyacinthe, QC, J2S 2M2 Canada;2. Lactanet, Sainte-Anne-de-Bellevue, QC, H9X3R4 Canada;3. Département des Sciences Animales, Université Laval, Québec City, QC, G1V 0A6 Canada;4. Department of Population Medicine, University of Guelph, ON, N1G 2W1 Canada;5. Complexe de diagnostic et d''épidémiosurveillance vétérinaire du Québec, Ministère de l''Agriculture, des Pêcheries et de l''Alimentation du Québec, St-Hyacinthe, QC, J2S 2M2 Canada
Abstract:The objective of this cross-sectional study was to standardize a reliable and repeatable swabbing technique using ATP luminometry (light emission proportional to the amount of ATP with result provided in relative light units RLU]) to describe the cleanliness of various feeding equipment used for preweaning calves in dairy farms. A total of 7 Québec commercial dairy herds were selected conveniently. Following visual hygiene scoring, the cleanliness of every available piece of feeding equipment was assessed using direct surface swabbing for buckets and nipples with Hygiena UltraSnap swabs. A liquid rinsing technique was used for esophageal feeders, bottles, and automatic milk feeders (AMF) with UltraSnap, AquaSnap, and MicroSnap swabs. To validate direct swabbing technique of buckets, a stage within and between operators was realized, as well as a conventional bacterial culture. A total of 519 swab samples were obtained from 201 pieces of equipment. The median (interquartile range) contamination in RLU for a bottle, esophageal feeder, AMF, bucket and nipple was 2 (1;6), 2 (0;12), 52 (19;269), 886 (128;7,230) and 899 (142;6,928), respectively. The direct swabbing technique, which consists in swabbing directly the surface of an equipment, showed excellent correlation for intrarater reliability (intraclass correlation (ICC) = 0.93; 95% CI: 0.88–0.96). The interoperator (2 sessions with 3 different operators) reliability also showed high correlation (ICC = 0.88; 95% CI: 0.78–0.94 for the first session, and ICC = 0.89; 95% CI: 0.79–0.95 for the second session). Luminometer values were positively associated with the visual score of esophageal feeders, AMF and buckets. A positive correlation between bacterial culture and direct swabbing of buckets was also found for the UltraSnap (rs = 0.653; 95% CI: 0.283–0.873; P = 0.0003) and MicroSnap (rs = 0.569, 95% CI: 0.309–0.765; P = 0.002). This study describes a standardized and practical on-farm swabbing technique for assessing the hygienic status of feeding equipment by luminometry, which can be integrated in the investigation of preweaning dairy calves problems.
Keywords:calf health  hygiene  contamination  luminescence  rapid testing
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号