首页 | 本学科首页   官方微博 | 高级检索  
     


Time resolution of a 6-gap resistive plate chamber with strip readout
Authors:V. V. Ammosov  O. P. Gavrishchuk  V. A. Gapienko  V. G. Zaets  N. A. Kuz’min  Yu. M. Sviridov  A. A. Semak  S. Ya. Sychkov  E. A. Usenko  A. I. Yukaev
Affiliation:1.Institute for High Energy Physics,Protvino, Moscow oblast,Russia;2.Laboratory of High Energy Physics,Joint Institute for Nuclear Research,Dubna, Moscow oblast,Russia
Abstract:A 6-gap glass resistive plate chamber with a strip readout was tested on the beam of the U-70 accelerator at the Institute for High Energy Physics. A time resolution of ∼45 ps was attained at an efficiency of >98%. The position resolution along a strip was estimated to be ∼1 cm.
Keywords:
本文献已被 SpringerLink 等数据库收录!