摘    要:针对河津电厂使用的德国阳光免维护电池及其它电厂的免维护电池在运行中出现的问题,从运行的角度,介绍了几种日常工作中的维护方法,主要有:充电电压的整定、环境温度对充电电压的影响、蓄电池的检测、充放电维护等。使其在运行中少出问题,延长寿命,更好地服务于电力系统。

关 键 词:免维护蓄电池  运行  维护
文章编号:1671-0320(2006)05-0068-03
修稿时间:2005-05-10

Maintainance of Maintain Free Batlerg in Operation
YANG Bing-bo. Maintainance of Maintain Free Batlerg in Operation[J]. Shanxi Electric Power, 2006, 0(5): 68-70
Authors:YANG Bing-bo
Abstract:To the questions appearing in operating of nonmaintaining battery of German sunshine which the power plant of Hejin uses,in term of operating,is introducing several kinds of maintenance method in routines,as follows,mainly charge voltage exactly make,the influence of environment temperature to charge,measuring of battery of voltage,the maintain to etc.to charge and discharge etc.Makes it go wrong few in running,lengthen the life-span,serve the power system better.