首页 | 本学科首页   官方微博 | 高级检索  
     

高压加热器运行故障分析及改造
引用本文:陈功. 高压加热器运行故障分析及改造[J]. 热力发电, 2006, 35(12): 39-40
作者姓名:陈功
作者单位:华亭电厂,甘肃,华亭,744100
摘    要:分析了某电厂2台25 MW汽轮机高压加热器运行故障发生的原因,提出了相应的技术改造措施。高加系统和疏水器改造后,运行正常,机组安全可靠性和经济性提高。

关 键 词:高压加热器  泄漏  疏水器  无水位运行  自调节液位控制装置
文章编号:1002-3364(2006)12-0039-02

ANALYSIS OF TROUBLES OCCURRED IN OPERATION OF HIGH-PRESSURE HEATER AND RETROFIT THEREOF
CHEN Gong. ANALYSIS OF TROUBLES OCCURRED IN OPERATION OF HIGH-PRESSURE HEATER AND RETROFIT THEREOF[J]. Thermal Power Generation, 2006, 35(12): 39-40
Authors:CHEN Gong
Abstract:The causes leading to troubles in operation of the high - pressure heater in one power plant have been analysed, and corresponding measures for technical retrofit being put forward. After retrofitting the high - pressure heater system and drain trap, the operation is normal, enhancing the safety, reliability and economic behavior of the u-nit.
Keywords:high-pressure heater  leakage  drain trap  operation without water-level