Role of nitrogen lewis basicity in boronate affinity chromatography of nucleosides |
| |
Authors: | Tuytten Robin Lemière Filip Esmans Eddy L Herrebout Wouter A van der Veken Benjamin J Maes Bert U W Witters Erwin Newton Russell P Dudley Ed |
| |
Affiliation: | Department of Chemistry, Nucleoside Research and Mass Spectrometry Unit, and Center for Proteomics and Mass Spectrometry, University of Antwerp, Antwerp, Belgium. |
| |
Abstract: | Urinary modified nucleosides have a potential role as cancer biomarkers, and most of the methods used in their study have utilized low-pressure phenylboronate affinity chromatography materials for the purification of the cis-diol-containing nucleosides. In this study, a boronate HPLC column was surprisingly shown not to trap the nucleosides as would be expected from experience with the classic Affigel 601 resin but showed only partial selectivity toward cis-diol groups while other groups exhibited better retention. In aprotic conditions, trapping of nucleosides was possible; however, the selectivity toward cis-diol-containing compounds was lost with the Lewis basicity of available nitrogens being the main determinant of retention. The experimental findings are compared to and confirmed by DFT calculations. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|