ANSYS在冷却塔结构计算中的应用
引用本文:宋平平,李琪,李永梅. ANSYS在冷却塔结构计算中的应用[J]. 山西建筑, 2009, 35(32): 73-74
作者姓名:宋平平  李琪  李永梅
作者单位:1. 扬州大学建筑科学与工程学院,江苏扬州,225009
2. 徐州公正工程造价咨询有限公司,江苏徐州,221002
摘    要:通过建立冷却塔的有限元模型,分析了其结构在自重及风荷载的作用下塔筒的应力分布规律及变形分布规律,并计算了部分单元的承载力情况,得出局部筒壁子午向配筋量不满足规范要求,应进行结构加固。

关 键 词:冷却塔  荷载  ANSYS  模型  承载力

The application of ANSYS in cooling tower structure calculation
SONG Ping-ping,LI Qi,LI Yong-mei. The application of ANSYS in cooling tower structure calculation[J]. Shanxi Architecture, 2009, 35(32): 73-74
Authors:SONG Ping-ping  LI Qi  LI Yong-mei
Affiliation:SONG Ping-ping, LI Qi, LI Yong-mei
Abstract:By building finite element model of cooling tower, the tower tube stress distribution rule and deformation distribution role of the structure on the dead loading and wind loading effect were analyzed. The bearing situation of some units were calculated, it concluded that part tube wall meridian direction reinforcement didn't satisfy standard requirement and should be structural reinforced.
Keywords:ANSYS