首页 | 本学科首页   官方微博 | 高级检索  
     


Pressure/current characteristics of a magnetron cold cathode gauge
Authors:A Vesel  M Mozetic  M Zumer  V Nemanic  B Zajec
Affiliation:Institute of Surface Engineering and Optoelectronics, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia
Abstract:The gauge characteristics for a magnetron gauge in the pressure range 10−8-10−5 mbar with nitrogen as a test gas have been studied. The discharge current versus pressure was measured at different magnetic fields from 0.10 to 0.15 T and anode voltages from 4.0 to 7.0 kV. The results showed that a change of slope appeared at pressures between 5×10−8 and 5×10−7 mbar. At higher magnetic fields, a change of slope appeared at lower pressures. The slope of the curve below the inflection was higher than that above the inflection. At the lowest magnetic field (0.10 T), a divergence of the curves was observed at pressures below the inflection. The slope of the curve showed no clear dependence on applied voltage.
Keywords:52  80  Sm  52  80  Vp
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏