摘    要:江门鹤山供电局生产调度综合楼主楼为19层办公大楼,裙楼4层,总高度74m,文中介绍了该工程结构设计的一些关键问题,包括基础选型、大跨度梁、楼板大开洞、梁托柱、超长地下室无缝设计等,供设计人员参考.

关 键 词:高层建筑  基础选型  大跨度梁  楼板大开洞  梁托柱  超长地下室

Structral Design of Heshan Power Supply Bureau
Liang Zhihong.Structral Design of Heshan Power Supply Bureau[J].Guangdong Architecture Civil Engineering,2011(4):25-27.
Authors:Liang Zhihong
Affiliation:Liang Zhihong(The Architectural Design & Research Institute of Guangdong Province Guangzhou 50010,China)
Abstract:Dispatch Center Building of Heshan,Jiangmen Power Supply Bureau including a nineteen-story main building for office and a four-story podium for dispatch,with a total height of 74m.This paper instroduces the key issues in the project design of foundation selection,long-span beam,wide-hole floor,corbel column,super-long basement seamless design.