摘    要:分析了石油化工装置中多级离心泵产生振动超标的原因,并结合石油化工装置多级离心泵的采购管理及现场运行维护经验,从泵的设计、制造、安装等方面进行分析,得到了消除石油化工装置中多级离心泵振动超标的对策。

关 键 词:多级离心泵  振动超标  原因  对策

Causes Analysis of Vibration Occurred in Multi-stage Pump and Counter Measure
ZHANG Jian-chen.Causes Analysis of Vibration Occurred in Multi-stage Pump and Counter Measure[J].Process Equipment & Piping,2010,47(4):38-40,50.
Authors:ZHANG Jian-chen
Affiliation:ZHANG Jian-chen ( SINOPEC Shanghai Petrochemical Stock Co. , Lid, Shanghai 200540, China)
Abstract:The causes of vibration beyond limit occurred in multi-stage pump used in petrochemical plant were analyzed in this article. Combined with the experiences in procurement and onsite maintenance of multi-stage pumps, and based on the design, manufacture and installation of the pumps, the counter measures for removing the vibration beyond limit occurred in multi-stage pumps were obtained.
Keywords:multi-stage pump  vibration which is beyond limit  cause  counter measure