首页 | 本学科首页   官方微博 | 高级检索  
     

三菱700 MW机组锅炉燃烧器烧损和磨蚀的原因分析
引用本文:徐乾. 三菱700 MW机组锅炉燃烧器烧损和磨蚀的原因分析[J]. 黑龙江电力, 2001, 23(4): 257-257,261
作者姓名:徐乾
作者单位:广东珠海电厂
摘    要:珠海发电厂三菱700MW机组2号锅炉小修时,发现燃烧器喷嘴,隔板发生较大的磨损和侵蚀,结合2号锅炉性能试验和实际运行工况,分析原因,提出处理方法,以及今后运行中应注意的问题。

关 键 词:燃烧器 磨损 烧损 锅炉 700MW机组 发电厂
文章编号:1002-1663(2001)04-0257-01

Analysis and Disposal of Reason of Burner Sparkwear and Corrosion about Mitsubishi Co.700MW Unit Boiler
XU Qian. Analysis and Disposal of Reason of Burner Sparkwear and Corrosion about Mitsubishi Co.700MW Unit Boiler[J]. Heilongjiang Electric Power, 2001, 23(4): 257-257,261
Authors:XU Qian
Abstract:During temporary repair of No.2boiler of zhuhai power plant Mitsubishi Co.700MW Unit,found burner nozzle and diaphragm took place serious wearing and corrosion.Combined with No.2boiler performance test and actual operating condition,analysed reason,point out disposal method,and attnetive problem during future operation.
Keywords:burner  wearing  co rrosion