Two-dimensional analysis of linear induction motor using Fourier's series method |
| |
Authors: | Dr-Ing E A Mendrela Dr-Ing E Gierczak |
| |
Affiliation: | (1) Department of Electrical Engineering, Technical University of Kielce, Al. 1000-cia PP-7, 25-314 Kielce, Poland |
| |
Abstract: | Contents A single sided linear induction motor with finite length of the primary is considered. Calculations of magnetic flux density, secondary current, forces and power losses in two layers of a secondary are based on Fourier's series method. Variation of magnetic flux density across an air-gap and finite values of permeability and conductivity of the secondary back iron were taken into account in the computational model. Calculations were compared with test results.
Zweidimensionale Analyse des linearen Induktionsmotors nach der Methode harmonischer Fourierreihen Übersicht Es wird ein einseitiger linearer Induktionsmotor bei Berücksichtigung endlicher Strombelaglänge betrachtet. magnetische Induktion, Strom-, Kraft-und Verlustdichte in zwei Schichten des Sekundärteiles wurden auf Grund der Methode harmonischer Fourierreihen berechnet. Im rechnerischen Modell wurde die Änderung der magnetischen Induktion im Spalt und der endliche Wert der magnetischen Induktion im Spalt und der endliche Wert der magnetischen Permeabilität sowie der Leitfähigkeit von Eisen im Sekundärteil berücksichtigt. Die Berechnungen wurden mit Ergebnissen experimenteller Untersuchungen verglichen. List of symbols and abbreviations
a
primary width
-
B
magnetic flux density
-
b
slot opening
-
c
secondary width
-
d
conducting plate thickness
-
E
electric field intensity
-
F
force
- f
force density
-
H
magnetic field intensity
-
J
current density
-
J
s
primary linear current density
-
J
r
secondary linear current density
-
K
t
finite primary width correction factor
-
K
b
Carter's coefficient
-
k, u, i
harmonic and wave number
-
L
primary length
-
q
number of slots per pole per phase
-
s
slip
-
v
secondary speed relative to primary
-
v
ijk
speed of the kui field harmonic
-
w
s
number of wires per slot
- P
e
secondary power losses
- p
e
secondary power loss density
-
modified air-gap length
-
a
actual air-gap length
-
permeability
-
modified air-gap length
-
permeability
-
modified secondary conductivity
-
a
actual secondary conductivity
-
s
–L]
distance between adjacent primaries
-
t
tooth pitch
-
z
pole pitch
-
Q
-
Q*
conjugate value ofQ |
| |
Keywords: | |