Comparison of measured value and calculated value of multiplestability in forced-flow cooled superconductors |
| |
Authors: | Amano T. Nakamura S. Yamada T. Watabe S. Kamitani A. |
| |
Affiliation: | Mitsubishi Electr. Corp., Hyogo; |
| |
Abstract: | The multiple stability observed exclusively in forced-flow cooled superconductors is numerically calculated, and the result is quantitatively compared with the value measured by J.W. Lue et al. (1980). The calculated and measured values agreed well in certain cases, and did not in others. Based on this comparison, the effects of the transient heat transfer coefficient and ohmic heat generation on the quantitative prediction of stability are discussed. From this comparison, it is learned that a precise understanding of the transient heat transfer coefficient is essential for reliable predictions, and also that the ordinary evaluation method of ohmic heat generation, which considers the flux-flow resistance, tends to overevaluate the situation |
| |