摘    要:分布式发电、储能及柔性负荷在配电网的大量接入引起配电网潮流的频繁变化,构建准确、简洁的节点注入功率与运行参数的函数模型对主动配电网的规划和运行至关重要。结合配电网辐射状拓扑结构,提出了一种对节点注入功率变化具有宽适应性的潮流灵敏度分析模型。所提灵敏度分析模型具体包含节点注入功率对线路损耗的二次形式的灵敏度模型、节点注入功率对节点电压的线性形式的灵敏度模型和节点注入功率对线路潮流的二次形式的灵敏度模型。对灵敏度模型应用于存在弱环网的配电系统时的有效性进行了分析,利用IEEE 33节点配电系统和含环网的IEEE 123节点配电系统进行仿真分析,仿真结果证明了所提灵敏度模型的有效性。

关 键 词:主动配电网  线路功率  线路损耗  节点电压  灵敏度模型
收稿时间:2019/5/9 0:00:00
修稿时间:2019/11/18 0:00:00

Power Flow Sensitivity Analysis Model with Wide Adaptability for Active Distribution Networks
LIU Qi,WANG Shouxiang,JI Xingquan.Power Flow Sensitivity Analysis Model with Wide Adaptability for Active Distribution Networks[J].Automation of Electric Power Systems,2020,44(13):81-88.
Authors:LIU Qi  WANG Shouxiang  JI Xingquan
Abstract:The large-scale integration of distributed generations, energy storage systems and flexible loads in the distribution network causes frequent changes in power flows of the distribution network. It is very important for the planning and operation of active distribution networks to build an accurate and concise function model of node injection power and operation parameters. Combined with the radial topology of the distribution network, a power flow sensitivity analysis model with wide adaptability to the change of node injection power is proposed. The proposed model includes a quadratic sensitivity model of nodal power injections to line losses, a linear sensitivity model of nodal power injections to nodal voltages, a quadratic sensitivity model of nodal power injections to branch power. The effectiveness of the sensitivity model applied to the distribution system with weak ring network is analyzed. The IEEE 33-bus distribution system and the IEEE 123-bus distribution system with ring network are used for simulation analysis. The simulation results prove the effectiveness of the proposed sensitivity model.