首页 | 本学科首页   官方微博 | 高级检索  
     

提高直插式瞬发电雷管安全电流的新途径
引用本文:房振宽,郑险光. 提高直插式瞬发电雷管安全电流的新途径[J]. 爆破器材, 1992, 0(5)
作者姓名:房振宽  郑险光
作者单位:山东省淄博矿务局五二五厂,山东省淄博矿务局五二五厂
摘    要:文章介绍了用B型镍铬丝代替A型镍铬丝作桥丝,以提高直播式瞬发电雷管的安全电流,使其达到《工业电雷管》GB8031的标准要求。实践证明,这是一条可行的途径。

关 键 词:电雷管  桥丝  安全电流

A New Way of Improving Safety Ignition Current for Insert-Bridgewire Instantaneous Electric Detonators (IBIED)
Fang Zhenkuan,Zheng Xianguang. A New Way of Improving Safety Ignition Current for Insert-Bridgewire Instantaneous Electric Detonators (IBIED)[J]. Explosive Materials, 1992, 0(5)
Authors:Fang Zhenkuan  Zheng Xianguang
Affiliation:525 plant of Zibo Mineral Bureau
Abstract:In this paper, we use type B nichrome wire as a substitute for type A one as bridgewire, for inproving safety ignition current for insert-bridgewire instantaneous electric detonators and coming up to "Electric Detonators"GB8031 standard. The experiment results show that it is a good way to improve safety ignition current for IBIED by using type B nichrome wire.
Keywords:electric detonator  bridgewire  safety ignition current