摘    要:针对尿素装置氨水槽氨水浓度高,造成水解一解吸系统超压以及中压、常压系统尾气放空氨含量增多等问题,进行原因分析,制定相应的处理措施,以达到降低氨耗的目的.

关 键 词:尿素装置  氨水浓度  系统优化  氨耗

REASONS OF HIGH CONCENTRATION OF AQUEOUS AMMONIA IN AMMONIA TANK IN UREA PLANT AND SOLUTIONS
Zhou Jing,Xiao Hong.REASONS OF HIGH CONCENTRATION OF AQUEOUS AMMONIA IN AMMONIA TANK IN UREA PLANT AND SOLUTIONS[J].Large Scale Nitrogenous Fertilizer Industry,2014(3):172-174.
Authors:Zhou Jing  Xiao Hong
Affiliation:( SINOPEC Hubei Fertilizer Branch ,Zhijiang 443200)
Abstract:High concentration of aqueous ammonia in ammonia tank in urea plant will cause of pressure in hydrolysis-desorption system, and ammonia content in vent tail gas in normal pressure will increase. Reasons were analyzed to find a solution to reduce ammonia consumption.