首页 | 本学科首页   官方微博 | 高级检索  
     


Improved device performance by multistep or carbon co-implants
Authors:Liefting   R. Wijburg   R.C.M. Custer   J.S. Wallinga   H. Saris   F.W.
Affiliation:MESA Res. Inst., Twente Univ., Enschede;
Abstract:High-energy ion implantation is used for forming the collector in vertical bipolar transistors in a BiCMOS process. Secondary defects, remaining after annealing the implant damage, give rise to an increased leakage current and to collector-emitter shorts. These shorts reduce the transistor yield. The use of multiple step implants or the introduction of a C gettering layer are demonstrated to avoid dislocation formation. Experimental results show that these schemes subsequently lower the leakage current and dramatically increase device yield. The presence of C can cause increased collector/substrate leakage, indicating that the C profile needs to be optimized with respect to the doping profiles
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏