首页 | 本学科首页   官方微博 | 高级检索  
     

关于通信设备的直流电缆截面的选择
引用本文:郑晨曦.关于通信设备的直流电缆截面的选择[J].电信工程技术与标准化,2005(5):18-21.
作者姓名:郑晨曦
作者单位:福建省邮电规划设计院有限公司,福州,350003
摘    要:目前正在运行的通信设备的直流电缆截面太大,安装和维护时施工困难,浪费投资,而且实际的负载电流偏小,压降很低.希望设计单位和设备厂家能够对通信设备的电压降重新进行整定和计算,将电缆截面降低到最小程度.在不影响设备正常运行的条件下,降低施工难度、节省投资.

关 键 词:全程压降  设备允许压降  蓄电池组电压

Choice of DC Cable Section Size of Communication Equipments
Zheng Chenxi.Choice of DC Cable Section Size of Communication Equipments[J].Telecom Engineering Technics and Standardization,2005(5):18-21.
Authors:Zheng Chenxi
Abstract:The DC cable section size of the existing communication equipments is too big, which results either in the difficulty of installation and maintenance or in the insufficient electric current and lower voltage- in-need. They hope that the design unit and equipment manufacturer will review and re-calculate the voltage-in-need of communication equipments to cut the cable section size to the minimum in order to decrease the construction difficulty and save the investment on condition that keep the equipment in gear.
Keywords:allowed voltage for whole course  allowed voltage for equipment  accumulator pile voltage