首页 | 本学科首页   官方微博 | 高级检索  
     


Conventional and back-side focused ion beam milling for off-axis electron holography of electrostatic potentials in transistors
Authors:Dunin-Borkowski Rafal E  Newcomb Simon B  Kasama Takeshi  McCartney Martha R  Weyland Matthew  Midgley Paul A
Affiliation:Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ, UK. rafal.db@msm.cam.ac.uk
Abstract:Off-axis electron holography is used to characterize a linear array of transistors, which was prepared for examination in cross-sectional geometry in the transmission electron microscope (TEM) using focused ion beam (FIB) milling from the substrate side of the semiconductor device. The measured electrostatic potential is compared with results obtained from TEM specimens prepared using the more conventional 'trench' FIB geometry. The use of carbon coating to remove specimen charging effects, which result in electrostatic fringing fields outside 'trench' specimens, is demonstrated. Such fringing fields are not observed after milling from the substrate side of the device. Analysis of the measured holographic phase images suggests that the electrically inactive layer on the surface of each FIB-milled specimen typically has a thickness of 100 nm.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏