首页 | 本学科首页   官方微博 | 高级检索  
     


Single-phase and two-phase cooling with an array of rectangular jets
Affiliation:1. Purdue University, School of Mechanical Engineering, International Electronic Cooling Alliance, 585 Purdue Mall, West Lafayette, IN 47907, USA;2. Raytheon Missile Systems, Tucson, AZ 85706, USA;1. Center for Space Technologies, School of Physics and Engineering, Sun Yat-Sen University, Guangzhou 510275 PR China;2. School of Chemistry and Chemical Engineering, Sun Yat-Sen University, Guangzhou 510275 PR China;3. State key laboratory of Optoeletronic Materials and Technologies, Sun Yat-Sen University, Guangzhou 510275 PR China;1. School of Mechanical and Electrical Engineering, Guilin University of Electronic Technology, No. 1 Jinji Road, Guilin, Guangxi 541004, China;2. Beijing Institute of Space Mechanics & Electricity, No. 104 Youyi Road, Haidian District, Beijing 100094, China;1. Laboratory of Heat and Mass Transfer (LTCM), École Polytechnique Fédérale de Lausanne (EPFL), Switzerland;2. IBM Research GmbH, Zurich Research Laboratory, Säumerstrasse 4, CH-8803 Rüschlikon, Switzerland
Abstract:Experiments were performed to explore the effects of jet width, impingement velocity, and inlet subcooling on the cooling performance of an array of three confined rectangular FC-72 and ethanol jets impacting a 3.0 cm × 3.0 cm heated surface. The single-phase heat transfer coefficient increased with increasing jet velocity and/or jet width. A correlation for single-phase cooling was constructed by dividing the flow into impingement zones and confinement channel flow regions that are dominated by wall jet flow. Increases in jet velocity, jet width, and/or subcooling broadened the single-phase region preceding the commencement of boiling and enhanced critical heat flux (CHF). A new correlation was developed which fits the CHF data with good accuracy. Overall, better cooling performance was realized for a given flow rate by decreasing jet width. Pressure drop was for the most part quite modest, even for the smallest jet width and highest velocity tested. Overall, these results prove the present cooling scheme is highly effective at maintaining fairly isothermal surface conditions, with spatial variations of less than 1.2 and 2.6 °C for the single-phase and boiling regions, respectively. These results demonstrate the effectiveness of the present jet-impingement scheme for thermal management of next generation electronics devices and systems.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号